1.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 31-35, 2022.
Article in Chinese | WPRIM | ID: wpr-932893

ABSTRACT

Objective:To automatically synthesize Al 18F-1, 4, 7-triazacyclononane-1, 4, 7-triacetic acid (NOTA)-fibroblast activation protein inhibitor (FAPI)-04, perform PET/CT imaging in vivo, and evaluate its diagnostic efficacy on tumors. Methods:Al 18F-NOTA-FAPI-04 was produced in All-in-one automatic synthesis module and its quality control was conducted by high performance liquid chromatography (HPLC) equipped with a radioactive detector. Al 18F-NOTA-FAPI-04 PET/CT imaging was performed in normal BALB/c mice ( n=3) and 4T1 breast cancer models ( n=3) to determine its biodistribution. Then Al 18F-NOTA-FAPI-04 and 18F-FDG PET/CT imaging were performed in a hepatocellular carcinoma patient (male, 51 years old). Results:The synthesis time of Al 18F-NOTA-FAPI-04 was about 35 min, and the radiochemical yield was (25.2±1.9)% (attenuation correction, n=3). The product was colorless transparent solution with pH value of 7.0-7.5, and the specific activity was (46.11±3.07) GBq/μmol (attenuation correction, n=3). The radiochemical purity was above 99.0% and was still above 98.0% at room temperature after 6 h. PET/CT imaging in mice showed that physiological uptake of Al 18F-NOTA-FAPI-04 was mainly in biliary system and bladder, and Al 18F-NOTA-FAPI-04 highly concentrated in tumor xenografts. PET/CT imaging in the patient showed that Al 18F-NOTA-FAPI-04 obtained high tumor background ratio (TBR) values of 4.1, 8.9, 5.4, 4.8, 2.2 in parasternal lymph nodes, anterior diaphragmatic lymph nodes, hilar lymph nodes, pancreaticoduodenal ligament lymph nodes, abdominal aortic lymph nodes, respectively, while TBR values were 1.0, 2.8, 5.0, 2.1, 1.1 by 18F-FDG. Conclusions:Al 18F-NOTA-FAPI-04 can be synthesized with short time, high radiochemical yield and good stability using All-in-one module. Al 18F-NOTA-FAPI-04 PET/CT imaging has high contrast and excellent diagnostic efficacy on tumors.

2.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 606-609, 2019.
Article in Chinese | WPRIM | ID: wpr-796727

ABSTRACT

Objective@#To synthesize and analyze 18F-prostate specific membrane antigen (PSMA)-1007, followed by its imaging in prostate cancer.@*Methods@#Based on one-step method, 18F-PSMA-1007 was produced by the CFN-MPS-200 automatic synthesis module and its quality analysis was conducted. 18F-PSMA-1007 PET/CT imaging was performed in a prostate cancer patient (66 years old).@*Results@#The synthesis time of 18F-PSMA-1007 was about 50 min, and the radiochemical yield was (25.0±5.0) % (attenuation correction, n=3). The radiochemical purity was above 99.0% and was above 98.0% after 6 h. The product was colorless transparent solution with pH value of 7.0-7.5, and the specific activity was (410.0±11.0) MBq/ml and the radioactive nuclear purity was above 99.0%. PET/CT imaging in the patient showed that 18F-PSMA-1007 was highly concentrated in prostate cancer with maximum standardized uptake value (SUVmax) of 40.9.@*Conclusion@#Based on CFN-MPS-200 multifunction synthesis module, 18F-PSMA-1007 can be stably synthesized with high radiochemical yield and can be concentrated in prostate cancer.

3.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 606-609, 2019.
Article in Chinese | WPRIM | ID: wpr-791569

ABSTRACT

Objective To synthesize and analyze 18 F-prostate specific membrane antigen ( PSMA)-1007, followed by its imaging in prostate cancer. Methods Based on one-step method, 18 F-PSMA-1007 was produced by the CFN-MPS-200 automatic synthesis module and its quality analysis was conducted. 18 F-PSMA-1007 PET/CT imaging was performed in a prostate cancer patient (66 years old). Results The syn-thesis time of 18F-PSMA-1007 was about 50 min, and the radiochemical yield was (25.0±5.0) % (attenua-tion correction, n=3). The radiochemical purity was above 99.0% and was above 98.0% after 6 h. The product was colorless transparent solution with pH value of 7.0-7.5, and the specific activity was (410.0± 11.0) MBq/ml and the radioactive nuclear purity was above 99.0%. PET/CT imaging in the patient showed that 18 F-PSMA-1007 was highly concentrated in prostate cancer with maximum standardized uptake value ( SUVmax ) of 40.9. Conclusion Based on CFN-MPS-200 multifunction synthesis module, 18 F-PSMA-1007 can be stably synthesized with high radiochemical yield and can be concentrated in prostate cancer.

4.
Journal of Biomedical Engineering ; (6): 157-162, 2015.
Article in Chinese | WPRIM | ID: wpr-266708

ABSTRACT

In order to investigate the features of multidetector CT (MDCT) and magnetic resonance imaging (MRI) as well as the corresponding pathogic basis of solitary fibrous tumor (SFT) in the pelvis, we collected the clinical data of 13 patients with pathologically confirmed SFT in pelvis, and retrospectively reviewed the MDCT and MRI appearances. Of these enrolled patients, 6 received MDCT scans, 5 underwent MRI scans, and 2 underwent both MDCT and MRI examinations. Shown on the MDCT and MRI, the maximum diameters of the masses ranged from 4.0 to 25.2 cm (averaged 11.8 cm). Six masses were lobulated, and seven were round or oval. In addition, all masses were well-defined and displaced the adjacent structures to some degrees. On the computed tomography, all masses were of isodensity on unenhanced scans in general, among which five masses were demonstrated with hypodense areas. On the MRI T1-weighted image, all lesions were isointense, of which patchy hypointense areas were detected in 3 cases and radial hypointense areas were in 3 cases, and the other one was presented with homogenous intensity. On T2-weighted images, most of the lesions were mixed hyperintense, of which 3 cases were of heterogenous hyperintesity, radial hypointense areas were detected in 3 patients, and the other one was homogenously intense. On enhanced computed tomography and MRI, large supplying vessels were found in 4 cases; 12 cases showed moderate to conspicuous enhancement, and the other one was presented with mild homogenous enhancement. Of the patients with moderate to conspicuous enhancement, patchy areas of non-enhancement were detected in 7 cases, radial areas of progressive enhancement were detected in 3 cases, and the remained 2 cases showed homogenous enhancement. On pathology, the radial area presented as progressive enhancement was fibrosis. During the follow-ups after surgery, 2 patients had local recurrence and 1 had metastasis to liver. In conclusion, the SFT in the pelvis are commonly presented as a large solid, well-defined and hypervascular mass with necrosis or cystic changes at some extents together with the displacement of adjacent structures. The radial area with hypointensity on T2-weighted image and with progressive enhancement on enhanced magnetic resonance imaging is an important feature of SFT, which can be helpful for the diagnosis of this mass.


Subject(s)
Humans , Magnetic Resonance Imaging , Neoplasm Recurrence, Local , Pelvis , Pathology , Retrospective Studies , Solitary Fibrous Tumors , Diagnosis , Pathology , Tomography, X-Ray Computed
5.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 873-874, 2012.
Article in Chinese | WPRIM | ID: wpr-425421

ABSTRACT

ObjectiveTo explore the potential value of diffusion weighted imaging(DWI) in the clinical diagnosis of soft-tissue tumors.MethodsDiffusion-weighted MRI was performed in 48 histologically proven soft-tissue tumor cases using diffusion-weighted spin-echo sequences.Of the 48 soft-tissue tumor cases,there were 28 cases of sarcoma and 20 cases of benign tumor.The apparent diffusion coefficient(ADC) values of a large region with no necrosis,scar tissue,hemorrhage or calcification representing the lesion were measured.ADC values of benign tumors,malignant tumors and normal muscles were compared.ResultsThe ADC value of the malignant tumors (0.95 ± 0.31 )× 10-3mm2/s was significantly lower than that of benign lesions( 1.87 ±0.66) × 10-3mm2/s and muscles( 1.62 ±0.50) × 10 -3mm2/s.There was no significant difference in ADC value between benign lesions and muscles.Sensitivity(75% ) and specificity(89% ) were obtained when the ADC value was 1.38 × 10-3mm2/s in the differentiation of benign and malignant tumors.ConclusionDiffusion-weighted MRI had potential value in differentiating benign softtissue tumors from malignant ones.

6.
Cancer Research and Clinic ; (6): 685-687, 2008.
Article in Chinese | WPRIM | ID: wpr-379723

ABSTRACT

Objective To assess the diagnostic value of multiple-slice spiral CT (MSCT) perfusion imaging technique in pancreatic cancer by measuring and comparing the dynamical characteristics of blood flow between normal pancreas and pancreatic cancer. Methods The CT perfusion imaging were obtained using Siemens Somatoma MSCT scanner in 44 patients with normal pancreas tissue and 18 patients with pancreatic cancer. The mean blood flow (BF),blood volume (BV), time to start (Trs), time to peak (TIP), permeability and patlak blood volume (pBV) were measured and statistically analyzed by using Siemens Body peHusion software package. Results The mean BF, BV, Trs, TIP, permeability and pBV of normal pancreas were: (90.60±29.25) ml·100 ml-1·min-1, (190.35±43.8) ml/L, (205.3±160.2) s, (1403.5±334.0)s, (99.47±49.9) 0.5 ml·100 ml-1·min-1, (157.8±52.5) ml/L, respectively. The mean BF, BV, TTS, TrP, per-meability and pBV of pancreatic cancer were (22.9±10. 63) ml·100 ml-1·min-1, (52.38±18.08) ml/L, (194.3±76.0) s, (1549.5± 308.5)s, (115.25±33.55) 0.5 ml·100 ml-1·min-1, (83.16±41.45) ml/L respectively. The mean BF, BV, pBV and permeability between normal pancreas and pancreatic carcinoma were statistically significant (P<0.01). However the mean TTS and TIP between normal pancreas and pancreatic carcinoma were not statistically significant (P>0.05). Conclusion There are significant differences between perfusion values of pancreatic carcinoma and normal pancreatic tissue, and MSCT perfusion imaging is helpful in diagnosing pancreatic carcinoma.

7.
Journal of Practical Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-545304

ABSTRACT

0.05).CTA 3D reconstruction in showing celiac artery branches was better than that with DSA , the observation of angles between celiac artery and abdominal aorta with MSCT was more convenient than that with DSA.4 cases with hepatic artery original abnormality were detected by MSCT ,they were the same as DSA.Conclusion MSCT is of important value in guidance of transcatheter arterial chemoembolization of HCC.

SELECTION OF CITATIONS